• Skip to primary navigation
  • Skip to main content
  • Skip to footer

Probe | Cased Hole | Wireline | Logging | Evaluation | Monitoring | Oil Well Tools

This site uses cookies to offer you a better browsing experience. If you consent close and accept this banner. EU Residents: Probe is committed to protecting personal data of our EU employees, contractors, customers, and vendors, regardless of where that data is processed. We have a robust security program and an established series of internal policies, processes, and practices across our organization to ensure that personal data of EU individuals is processed appropriately and protected in our information systems. You can find our GDRU policy at the bottom of this page. Click here for our Cookie Policy
MENUMENU
  • Home
  • About Us
    • The Probe Way
    • Mission, Vision & Values
    • History & Timeline
  • Search Products
        • Search Full Catalog & Services

        • Search Product Catalog
        • Customer Care Portal
        • Tool Rental Services
        • Petrophysics Services
        • Multi-String Isolation Logging Services
        • By Solution Platform

        • Well Integrity
        • Well Monitoring
        • Production Logging
        • Surface Systems
        • Formation Evaluation
        • Well Intervention
        • Geothermal & UHT Logging
        • Downhole Instrumentation
        • By Application

        • Bullnose
        • Gamma Ray CCL
        • Centralizers
        • Gamma Guns
        • Shooting CCLs
        • Slim PL Tools
        • Depth Loggers
        • Crossovers
        • Spectral Gamma
        • Fluid Density
        • Cement Evaluation
        • Perforating
        • Inclinometer
        • Temperature
        • Mandrels
        • Memory
        • Neutron
        • Panels
        • Calipers
        • Fluid Velocity
        • Ultra-Fast Gauges
        • Surface Acquisition
        • Correlation Tools
        • Pulsed Neutron
        • Pressure
        • Capacitance
        • Geothermal
        • Gauges
        • Firing Heads / Triggers
        • Leak Detection
        • Array Production Logging
        • Electro-Magnetic Thickness
        • Knuckle & Swivel Joints
        • Non-Ballistic Setting Tools
        • Tension-Compression
        • By Technology

        • HD Platform™
        • PTX Platform™
        • By Brand

        • ProMAC™
        • iQ™
        • RAS™
        • RADii®
        • Kuster®
        • IntelleX™
        • Quantum™
        • ProShooter™
        • KPerm™
        • Dimension™
        • ProTherma™
  • Careers
  • Newsroom
  • OTW Magazine
  • Locations
  • Contact
    • Sales & Product Inquiry
    • Repair & Support
    • Customer Care Gateway
    • Français
    • Español
    • 中文 (简体)
    • Deutsch

Cased-Hole Formation Evaluation

Probe’s range of industry leading cased-hole formation evaluation tools include the RAS™ (Reservoir Analysis Sonde), a 3 detector Pulsed Neutron tool, Spectral Gamma Ray as well as other tools such as Gamma Ray and Compensated Neutron to enable advanced reservoir evaluation in mature fields or new well completions. 

The cased-hole formation evaluation (FE) solutions suite is a group of cutting-edge cased-hole logging tools that provide comprehensive data to drive reservoir performance. The suite is extremely versatile, and includes the Reservoir Analysis Sonde (RAS™), a pulsed-neutron tool that can be combined with production logging and well integrity tools to deliver just the right data for your objectives. The tools in the suite operate in either memory or surface-readout mode and can be conveyed using wireline, slickline, or tubing.

ImageNameSKUDescription
Compensated Neutron Tool - PTX - 2 3/4 in.
Compensated Neutron Tool - PTX - 2 3/4 in.050-CN275-WSBLRatings & Dimensions Max Temperature 350°F (177°C) for 4 hours Maximum Pressure 20,000 psi (138 MPa) Outer Diameter 2.75 in (69.9 mm) Length 61.68 in (1566.67 mm)  Weight 60 lb. (27.2 kg) Min Csg/Tbg OD 4.5 in (115.0 …
Gamma Ray - CCL - Neutron - Inclinometer - Temp - PTX - 1 11/16 in.
Gamma Ray - CCL - Neutron - Inclinometer - Temp - PTX - 1 11/16 in.050-GN170-00CTRatings & Dimensions Max Temperature 350°F (177°C) for 4 hours Maximum Pressure 20,000 psi (138 MPa) Outer Diameter 1.69 in (42.93 mm) Length 96.46 in (2450.084 mm) | (M/U length 94.67 in (2404.62 mm)  Weight 35.0 lb (15.9 …
Gamma Ray - CCL - Neutron - Inclinometer Tool - PTX - 1 11/16 in.
Gamma Ray - CCL - Neutron - Inclinometer Tool - PTX - 1 11/16 in.050-GN170-00C3Ratings & Dimensions Max Temperature 350°F (177°C) for 4 hours Maximum Pressure 20,000 psi (138 MPa) Outer Diameter 1.69 in (42.93 mm) Length 96.46 in (2450.084 mm) | (M/U length 94.67 in (2404.62 mm)  Weight 35.0 lb (15.9 …
RAS Calibration Tank & Calibration Tank Insert - HD
RAS Calibration Tank & Calibration Tank Insert - HDCTI001The RAS Calibration / Verification Tank & Insert (CTI001) allows for periodic verification of correct tool operation and allows the tool to be tested at surface in a safe fashion. The tank is fabricated from steel and filled …
Reservoir Analysis Sonde (RAS) - HD - 1 11/16 In.
Reservoir Analysis Sonde (RAS) - HD - 1 11/16 In.RAS002The Reservoir Analysis Sonde (RAS002), is a multi-detector pulsed-neutron system for measuring reservoir saturation using Sigma and Carbon-Oxygen techniques. The sonde features three gamma detectors, the near and the far are high resolution Lanthanum Chloride detectors for Sigma …
Reservoir Analysis Sonde Safety Sub - HD - 1 11/16 In.
Reservoir Analysis Sonde Safety Sub - HD - 1 11/16 In.RSS001The Reservoir Analysis Sonde Safety Sub (RSS001), is a mandatory component in a Memory-RAS string. Positioned between the battery and MLT, it is equipped with pressure and temperature sensors to monitor borehole conditions against user programmable thresholds. A …
Reservoir Analysis Sonde Sigma - HD - 1 11/16 In.
Reservoir Analysis Sonde Sigma - HD - 1 11/16 In.RAS003The RAS003 is a multi-detector pulsed neutron tool for measuring reservoir saturation using Sigma techniques. The sonde features an array of three Sodium Iodide (NaI) detectors. The Sigma measurement is based on the near and far spacings, the …
Spectral Gamma Ray & CCL Tool - HD - 2 3/4 in.
Spectral Gamma Ray & CCL Tool - HD - 2 3/4 in.SGRCL2The Spectral Gamma Ray & Casing Collar Locator Tool (SGRCL2) operates on our common tool bus and can be combined with the Reservoir Analysis Sonde, Production Logging Tools or both. The SGRCL2 consist of a Casing Collar Locator …

Footer

For Customers

• Service and Repair
• Tech Support
• Request Quote
• Customer Portal

About Us

• The Probe Way
• Mission, Vision and Values
• Careers
• Solution Platforms
• Contact
• Locations


Copyright © 2023 Probe. All Rights Reserved. Probe is a registered trademark of Probe Technologies Holdings, Inc. in the United States.

  • ISO 9001 Information
  • Terms and Conditions
  • Privacy Statement
  • GDPR Request

Copyright © 2023 All Rights Reserved, Probe Technologies Holdings, Inc.